Files
nexus/knowledgebase/csd-wiki/ICSD/New-Farm-OPS-Requirments_688988220.md
2026-04-18 17:09:43 +08:00

1.9 KiB

New-Farm-OPS-Requirments_688988220

The purpose of this page is to describe the requirements in order to operate a new SMAX SaaS farm.

Monitoring:

  • APM:
    • A dedicated tenant with sample data deployed.
      • Disable SLT from the monitoring tenant
      • Applications to be created: SLA, Major functionalities, internal SLA. The SLA application name should include the farm id from CT.
      • Add the SLA application to SMAX SLA, Add the internal SLA application to SMAX internal SLA. Verify that the KPIs were populated properly.
  • SiteScope:
    • Connect bastion server to the domain
      • In case of a new region, ask PSDC to give the team members access and permissions in the SiteScope
      • Copy and modified scripts from existing farms to the new bastion server and update the environment variable accordingly.
      • Create an IAM user with sufficient permissions and use its keys for the AWS monitors.
      • Open Rabbitmq ports so the SiteScope can reach them
      • Make sure that the SiteScope can communicate with the bastion server.
      • Deploy monitors from the templates
  • Prometheus - enable Prometheus and Grafana

Setup:

  • Schedule idol compact to run periodically (daily\weekly)
  • Setup AWS backup jobs to backup RDS and EFS every 6 hours and keep the backups for one week
  • The bastion server should be deployed from an AMI. If this farm is deployed in a new region or account, work with PSDC to copy the AMI accordingly.

Administration:

  • Add the farm to CT.
  • Add a new environment to the PCS prod tenant.
  • Add a service health page to the farm. Make sure you can add incident reports and maintenance windows via the operational console
  • Verify that the APM data is populated.
  • In case of a new AWS account - set SAML authentication to all OPS people - ticket to PSDC.
  • Add password to passwords file in S3.
  • Create individual users with bo admin permissions to all ops members.
  • DWG reports - make sure the reports covers the new farm